Grease Trap - City of Chicago Super Basin
- Concrete:
- 5,000 psi @ 28 days
- 5% - 8% entrained air
- Rebar:
- ASTM A-615 grade 60
- Design criteria:
- a) City of Chicago configuration
- b) Loading per ASTM C857, including:
- -Earth cover: Min 0' - 9" Max 3' - 0"
- -AASHTO HS-20 wheel load & applicable impact
- -Vertical & lateral soil pressures determined using 120 PCF soil density
- -Ground water at 3' - 0" below grade
- c) Structural design performed using AASHTO strength design
- d) Reinforcing cover per ACI 318
- Notes:
- a) Contact UCP for custom configurations or modifications
- b) UCP suggests that 1-1/2" of non-shrink mortar should be placed at the base/lid joint by the installing contractor
- Openings are steel formed smooth surfaces to accomodate boots
| Item | Description | Qty |
|---|---|---|
| 1 | Precast concrete | 1 |
| 2 | 4T lifting anchors | 8 |
| 3 | 1" butyl rubber joint sealant (See Note "B" On Specs Sheet) | 2 rolls |
- Catalog PDF
- Screen Friendly PDF
- 754kb
- Printer Friendly PDF
- 296kb