Utility Building 11' - 0" x 20' - 0" x 8' - 0" ID

Concrete:
  • 5,000 psi @ 28 days
  • 5% - 8% entrained air
Rebar:
  • ASTM A-615 grade 60
Design criteria:
  • Walls comply with City of Chicago building codes and 1993 BOCA codes for 80 MPH winds no rating for the door
Finish:
  • Finish options
  • -Smooth concrete
  • -Exposed aggregate
  • -Painted
  • Doors have a primer coat of paint
Weight:
  • Left: 20,736#
  • Right: 22,668#
  • Roof: 16,263#
  • Total: 59,667#
Storage space:
1,803 cu ft
Item Description Qty
1 2 piece concrete building solid walls, floor, & roof. No waffles 1
2
  • Steel double door side by side 6' - 0" wide by 6' - 8" high active door with keyed lock and closure
  • Gasketed frame, tamper proof hinges and extruded aluminum threshold that locks open
  • Grey primer coating galvanized doors available
1
3 1 piece peaked roof post tensioned 1
4 Split culvert brackets 2
5 Vent with louver plate 2
3x4x4 Manhole - Typical Install PDF