Airport Light Base Type 2">

Concrete:
  • 5,000 psi @ 28 days
  • 5% - 8% entrained air
Rebar:
ASTM A-615 grade 60
Available duct entrances:
  • 2" Ø duct terminator sch 40
Design criteria:
  • Conforms with design developed by City of Chicago for airport locations reinforcing cover requirements as per ACI 318
Weight:
  • 2,981#
Item Description Qty
1 L-867 light base can size Ø 16" x 24" *
Deep class 1B stainless steel
(12" x 24" optional)
1
2 1-1/2" chamfer
3 2" PVC coated GRS elbow and transition pieces * 1
4 2" threaded coupling welded to bottom of can * 1
5 4T lifting anchor 2
6 2" Ø duct terminator 4
7 Rebar
* Contractor to provide